IR-3 Molecular Sieve
The KSC molecular sieve is used to reduce the iron and water (as nitric acid) content of N2O4. The molecular sieve is available to support all KSC and CCAFS programs.
Equipment | IR-3 Molecular Sieve |
Dimensions | 8′ long X 76″‘ wide X 8’1″ Tall |
Weight | 4,340 lbs |
DOT Code | Not applicable, KSC/CCAFS use only. |
MAWP | 150 psig |
Operating Pressure | 0-50 psig |
Relief Valve Setting | 150 psig |
Filter Rating | 0.2 micron absolute |
Approved Fluids | N2O4 |
Other Features | Move with Forklift. |